Sincerity Is Fundamental, Clients Is The First.

 

Strict Quality Control, Earnest Service Supply.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsFault Path Indicator

Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit

I'm Online Chat Now
Certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
Super friendly service, the Power Line Fault Indicator high quality as expected and very economy and environmental protection.

—— Bruce

This is the first time i do Underground Cable Fault Indicator business , after i received , it is work well. and now i want to order more.

—— Joseph

Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit

Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit
Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit

Large Image :  Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit Get Best Price

Product Details:

Place of Origin: Beijing , China
Brand Name: TYHD
Certification: type test report
Model Number: TYHD-AI9

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: standard export package
Delivery Time: within 3-5 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 3000 sets/month
Detailed Product Description
Dimension Of Repeater Station: H×W×T=388mm×366mm×368mm Applied Voltage Grade: 7~69kV Overhead Line
Rated Working Voltage: 5.5V-7.5V Work Time In Rainy Weather: ≥10 Days
High Light:

precision approach path indicator

,

electrical line locator

Safety criterion

Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport. When received, the repeater station shall be carefully checked for damage during transport, and in case of any problem, the carrier shall be reported immediately in written.

The package shall be carefully handled to avoid the damage and impact, the water shall be prevented during transport, and the corrosive materials cannot be transported in the same truck box as the package absolutely. If the equipment needs to be stored for a very long time before installation, it shall be in the clean place with good ventilation, the corrosive gas shall not be contained in the air, and it shall be stored with caution to avoid damage.

In order to avoid the unexpected conditions during application, the following safety guidelines shall be observed:

1. The Operating Manual must be read carefully during the site installation and debugging;

2. The power supply must be off when the mobile phone card is inserted or extracted via GPRS module;

3. The address information of data repeater station and the setup information of GPRS module must be recorded in detail;

4. The lead from solar energy to power panel must be reliable;

5. The installation of data repeater station must be reliable, and the solar panel shall face south (the direction with longer sunshine duration);

6. The person is strictly prohibited to stand under the pole and tower during installation.

Abstract

The fault indicator for overhead distribution lines is used indicating of phase-to-phase and phase-to-earth faults by determining short circuit, over-current and power features to detect faults and provide a local light indication. In addition, the indicator also has current measurement and wireless data communication capabilities, by sending the fault signal to FTU,in order to comply the function of the remote communication and the remote monitoring, to help operators to find the point of failure quickly and shorten the outage time and improve reliability.

Principle

The fault indicator installed on the overhead lines, which clipped on each phase so that to detect current and Voltage signal in this phase using itself clipped line structure. Through the low-power chip, it completes current calculation, short circuit, ground fault detection, and through built-in low-power RF modules achieves short distance wireless communication.

Functions

1. Wireless receiving: the fault point information and load current information sent by indicator are received via short-range wireless network mode.

2. GSM or GPRS forwarding: GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

3. Solar power supply: the solar power supply mode is applied, and the maintenance-free 8AH lead-acid battery or 12AH lithium iron phosphate battery is provided, with the working temperature range of both batteries of -35℃~75 ℃ and -20℃~75℃ separately.

4. Optional communication protocol: IEC870-5-101 protocol or 104 can be selected for the connection with the third party equipment to upload the fault and shift information.

5. Remote upgrade: the equipment program can be upgraded conveniently through master remote maintenance station.

6. Convenient maintenance: the parameter setting and equipment maintenance can be performed conveniently via wireless setting terminal.

7. Event recording: the device can record the maximum 500 pieces of SOE events, providing the rich data support for system fault analysis.

 

Technical parameters

 

Dimension of repeater station H×W×T=388mm×366mm×368mm
Weight of repeater station 6.75kg
Applied voltage grade 7~69kV overhead line
Circuit load current 0~630A
Rated working voltage 5.5V-7.5V
Overall power consumption <0.4W
Work time in rainy weather ≥10 days
Solar panel Organic glass protection, amorphous silicon, and 30 years of service life
Power of solar panel 12W/10V
Quantity of cooperation indicators 12
GPRS module E-GSM/GPRS 900/1800 dual band
Working temperature range (lead-acid battery) -35℃~75℃
Working temperature range (lithium iron phosphate) -20℃~75℃
MTBF >5×104 h

 

Alarming Mode Remote Fault Indicator , White 6.75kg Overhead Line Fault Locator For Remote Transmission Unit 0